Electrical data

Nominal wattage 17.50 W
Nominal voltage 220…240 V
Mains frequency 50/60 Hz
Total harmonic distortion < 25 %
Power factor λ ≥ 0.95
ECG efficiency ≧85 %

Dimensions & Weight

Length 238.00 mm
Width 36.00 mm
Height 30.00 mm
Product weight 190.00 g

Colors & materials

Casing material Plastic
Body material Plastic

Temperatures & operating conditions

Ambient temperature range -20…+50 °C
Maximum temperature at tc test point 85 °C
Max.housing temperature in case of fault 110 °C
Permitted rel. humidity during operation 5…80 %

Lifespan

ECG lifetime 10000 h
Number of switching cycles 10000

Capabilities

Dimmable No
Dimming interface Not dimmable
Overload protection Automatic reversible

Certificates & Standards

Approval marks – approval CE, RoHS, TUV, EAC
Protection class I
Type of protection IP20

LOGISTICAL DATA

Temperature range at storage -20…+80 °C
Product code Packaging unit (Pieces/Unit) Dimensions (length x width x height) Gross weight Volume
4058075534766 Unpacked
1
4058075536524 Bundle
5
300 mm x 240 mm x 50 mm 923.00 g 3.60 dm³
4058075536531 Shipping box
50
390 mm x 275 mm x 175 mm 9715.00 g 18.77 dm³
Product benefits
  • Specially designed for T8 UVC lamps to implement excellent lamp performance characteristics
  • No adverse effect from frequent on/off switching
  • Long lamp lifetime with matched driver
Areas of application
  • Water disinfection including UV units for drinking water, wastewater, swimming pools
  • For use with UV recirculators, UV irradiators, HVAC disinfection systems
  • Air purification
  • Surface sterilization
  • Food industry
  • Offices, schools
  • Healthcare
  • Warehouses
Product features
  • Lifetime: up to 20000 h (temperature at Ta=50 °C, Tc=80°C)
  • Power factor: ≥0.95
  • Safety complies with EN 61347-1, EN 61347-2-3
  • Radio interference complies with EN 55015
  • Harmonic distortion complies with EN 61000-3-2
  • EMC immunity complies with EN 61000-3-3, EN 61547
  • Performance complies with EN 62493