QTi 1X28/54 DIM

Product family benefits
  • Same luminous flux with direct and alternating current
  • Perfect lamp start for applications with motion sensors
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Very high efficiency thanks to cut-off technology
  • Automatic restart after lamp replacement
  • ECGs comply with MINERGIE standard due to very low standby consumption
  • Configurable emergency power characteristics

Product details

Nominal current 0.14 A
Nominal wattage + Power loss 30.10 W
Luminous flux at 35 °C 2800 lm
Number of lighting outlets 1
Nominal current 0.26 A
Nominal wattage + Power loss 59.00 W
Luminous flux at 35 °C 4800 lm
Number of lighting outlets 1
Nominal current 0.26 A
Nominal wattage + Power loss 59.00 W
Luminous flux at 35 °C 4450 lm
Number of lighting outlets 1
Nominal current 0.14 A
Nominal wattage + Power loss 30.10 W
Luminous flux at 35 °C 2600 lm
Number of lighting outlets 1
Nominal current 0.26 A
Nominal wattage + Power loss 59.00 W
Luminous flux at 35 °C 4800 lm
Number of lighting outlets 1
Nominal current 0.26 A
Nominal wattage + Power loss 58.80 W
Luminous flux at 35 °C 4450 lm
Number of lighting outlets 1
Nominal current 0.26 A
Nominal wattage + Power loss 58.80 W
Luminous flux at 35 °C 4850 lm
Number of lighting outlets 1

Electrical data

Input voltage AC 198…264 V
Nominal voltage 220…240 V
Mains frequency 50/60 Hz
Input voltage DC 154…276 V
Operating frequency 44…120 kHz
Max. ECG no. on circuit breaker 10 A (B)
17
Max. ECG no. on circuit breaker 16 A (B)
28
Inrush current 24 A

Light technical data

Starting time 0.6 s

Dimensions & weight

Length 360.0 mm
Width 30.0 mm
Height 21.0 mm
Mounting hole spacing, length 350.0 mm
Product weight 273.00 g
Wire preparation length, input side
8.0…9.0 mm
Wire preparation length, output side
8.0…9.0 mm
Cable cross-section, output side
0.5…1.5 / 0.5…1.0 mm²
Cable cross-section, input side
0.5…1.0 / 0.5…1.5 mm²

Temperatures & operating conditions

Ambient temperature range +10…+50 °C
Permitted rel. humidity during operation
5…85 %

Lifespan

ECG lifetime
100000 h

Capabilities

Dimming interface 1…10 V
Dimming range
1…100 %
Dimmable Yes
Overload protection Automatic switch off, reversible
Overheating protection Power reduction and switch off at T > 75 °C at the tc point
Suitable for emergency lighting Yes
Suitable for fixtures with prot. class I
End of lamp life safety shutdown EOL T.2

Certificates & standards

Approval marks – approval VDE / VDE-EMC / EL / EAC / RCM / CCC
Standards Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547
EEI – Energy Label A1 BAT
Protection class I
Type of protection IP20
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4050300870588 UNV
1
273.00g
4050300870595 VS
20
370mm x 96mm x 170mm 6320.00g 6.04dm³
EAN METEL code SEG number STK number EFO number ELDAS number
4050300870588 OSRQTI1X2854DIM 7980248 4030228 3322255 919481250
Product family benefits
  • Same luminous flux with direct and alternating current
  • Perfect lamp start for applications with motion sensors
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Very high efficiency thanks to cut-off technology
  • Automatic restart after lamp replacement
  • ECGs comply with MINERGIE standard due to very low standby consumption
  • Configurable emergency power characteristics
Areas of application
  • Suitable for emergency installations
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Suitable for luminaires of protection class I
Product family features
  • Control via 1…10 V interface
  • Supply voltage: 220…240 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Line voltage: 198…264 V
  • Dimming range: 1…100 % luminous flux
  • Lamp start: within 0.6 s
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Energy Efficiency Index EEI: A1 BAT
  • Overtemperature protection: Thermal management at high tc temperatures
  • Safety: to EN 61347-2-3
  • Lamp operation: to EN 60929
  • RI suppression: to EN 55015:2006+A1:2007+A2:2009/CISPR 15
  • Line harmonics according to EN 61000-3-2
  • Immunity according to EN 61547