Rated wattage | 23.00 W |
Nominal voltage | 220 240 V |
Operating frequency |
50
60 Hz
|
Nominal wattage | 23.00 W |
Nominal current |
0.11 A
|
Type of current | AC |
Max. lamp no. on circuit break. 10 A (B) | 43 |
Max. lamp no. on circuit break. B10 A - CCG without compensation | 43 |
Max. lamp no. on circuit break. B10 A - CCG with compensation | 37 |
Max. lamp no. on circuit break. B16 A - CCG without compensation | 69 |
Max. lamp no. on circuit break. B16 A - CCG with compensation | 62 |
Max. lamp no. on circuit break. 16 A (B) | 69 |
Power factor λ | > 0.90 |
Rated color temperature | 6500 K |
Nominal luminous flux | 3700 lm |
Rated luminous flux | 3700 lm |
Lumen main.fact.at end of nom.life time | 0.70 |
Light color (designation) | Cool Daylight |
Color temperature | 6500 K |
Luminous flux | 3700 lm |
Color rendering index Ra | 83 |
Standard deviation of color matching | ≤5 sdcm |
Starting time | < 0.5 s |
Warm-up time (60 %) | < 0.50 s |
Rated beam angle (half peak value) | 160.00 ° |
Length with base excl. base pins/connection | 1498.00 mm |
Tube diameter | 26.7 mm |
Base diameter | 28.0 mm |
Product weight | 295.00 g |
Overall length | 1500 mm |
Ambient temperature range | -20 +50 °C |
Maximum temperature at tc test point | 62 °C |
Lifespan | 60000 h |
Nominal lamp life time | 60000 h |
Rated lamp life time | 60000 h |
Number of switching cycles | 200000 |
Base (standard designation) | G13 |
Mercury-free | Yes |
Dimmable | No |
Type of protection | IP20 |
Standards | CE |
Energy efficiency class | A++ |
Energy consumption | 23 kWh/1000h |
Order reference | ST8AU-1.5M 23W/ |
Temperature range at storage | -20 +80 °C |
Product code | Packaging unit Piece / unit |
Gross weight | Volume | |
---|---|---|---|---|
4058075137820 | FLH 1 |
1605mm x 29mm x 29mm | 329.00g | 1.35dm³ |
4058075137837 | VS 10 |
1652mm x 210mm x 115mm | 4130.00g | 39.90dm³ |
EAN | SEG number | STK number | ELDAS number |
---|---|---|---|
4058075137820 | 8293867 | 4730987 | 941804520 |
Safety advice
Operation in outdoor applications in suitable damp-proof luminaires possible according to data sheet and installation instruction.
Legal advice
When used to replace a T8 fluorescent lamp the total energy efficiency and light distribution depends on the design of the lighting system.
References / Links
For current information see www.ledvance.com/substitube