HO CHIP CONTR 54 W/62

Product benefits
  • Excellent UV filter
  • The life of the sleeve is the same as the average lamp life

Product details

Electrical data

Nominal voltage 230 V
Rated lamp efficacy (HF data 25 °C) 52 lm/W
Rated wattage 54.10 W
Nominal wattage 54.00 W

Photometrical data

Rated luminous flux 2800 lm
Luminous flux at 25 °C 3140 lm
Luminous flux at 35 °C 3530 lm
Light color 62
Nominal luminous flux 2800 lm
Light color (designation) Yellow
Rated LLMF at 2,000 h 0.95
Rated LLMF at 4,000 h 0.93
Rated LLMF at 6,000 h 0.92
Rated LLMF at 8,000 h 0.90
Rated LLMF at 12,000 h 0.90
Rated LLMF at 16,000 h 0.90
Rated LLMF at 20,000 h 0.89
Luminous flux 2800 lm

Dimensions & weight

Tube diameter 16 mm
Length 1149 mm
Length with base excl. base pins/connection 1149.00 mm
Diameter 16.0 mm
Maximum diameter 16.0 mm

Temperatures & operating conditions

Rated ambient temp.w.max.luminous flux 35.0 °C

Lifespan

Service life
19000 h
Lifespan
24000 h
Rated lamp survival factor at 2,000 h 0.99
Rated lamp survival factor at 4,000 h 0.99
Rated lamp survival factor at 6,000 h 0.99
Rated lamp survival factor at 8,000 h 0.99
Rated lamp survival factor at 12,000 h 0.99
Rated lamp survival factor at 16,000 h 0.97
Rated lamp survival factor at 20,000 h 0.85
Operation mode LLMF/LSF HF
Rated lamp life time 24000 h
Nominal lamp life time 24000 h

Additional product data

Base (standard designation) G5
Mercury content 1.9 mg
Show WEEE picto Yes
Product remark Suitable for ECG operation only/Lamp designed for internal luminaire temperatures of 30…40 °C; optimum luminous flux achieved at 35 °C

Capabilities

Suitable for indoor Yes

Certificates & standards

Energy efficiency class B
Energy consumption 60 kWh/1000h
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4008321233400 UNV
1
1165mm x 17mm x 17mm 150.00g 0.34dm³
4008321233417 VS
10
1192mm x 43mm x 92mm 1676.00g 4.72dm³
EAN METEL code SEG number STK number EFO number
4008321233400 OSRFQ5462LUMLL 8329552 4931089 3860907
Product benefits
  • Excellent UV filter
  • The life of the sleeve is the same as the average lamp life
Areas of application
  • Microchip fabrication plants
  • Where UV and blue components have to be reduced to the absolute minimum
  • Industry
  • Print shops
Product features
  • Excellent filter at 500 nm
  • Long average lifetime: up to 24,000 h (with QUICKTRONIC ECG)
  • Dimmable
Equipment / Accessories
  • Suitable for operation on electronic and conventional control gears

Safety advice
Lamps with plastic sleeves, ambient temperature range: -10…+80 °C
Lamps with plastic sleeves, maximum shelf life: 5 years at 0…30 °C
Lamps with plastic sleeves must be replaced after average lifetime (B50) has been reached
In case of lamp breakage: www.ledvance.com/brokenlamp
Under standard conditions acc. IEC (free burning, 25 - 40°C ambient temperature) a typical increase of the emitted radiation power in the wavelength range < 500 nm up to 6 mW/klm per 10,000 hours of operation was determined. This corresponds to approx. 0.2% of the total emitted radiation power. This increase depends on the operation conditions.
For example for a T5 HO lamp at 80°C ambient temperature an increase of the emitted radiation power in the wavelength range < 500 nm of up to 50 mW/klm per 10,000 hours of operation can be observed. This corresponds to approx. 2% of the total emitted radiation power.
For applications in photo sensitive areas, routine maintenance is necessary. This must include verification of the amount of short wavelength light emitted, and, if required, lamp replacement.

System guarantee
OSRAM System+ Guarantee in combination with OSRAM ECGs

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit www.ledvance.com/system-guarantee