Electrical data

Rated lamp efficacy (HF data 25 °C) Under clarification by authority and standardization body
Rated wattage 36.00 W
Nominal wattage 36.00 W

Photometrical data

Rated lamp efficacy (standard condition) 57 lm/W
Rated luminous flux 2050 lm
Luminous flux at 25 °C 2300 lm
Light color 62
Nominal luminous flux 2050 lm
Light color (designation) Yellow
Rated LLMF at 2,000 h 0.95
Rated LLMF at 4,000 h 0.93
Rated LLMF at 6,000 h 0.91
Rated LLMF at 8,000 h 0.90
Rated LLMF at 12,000 h 0.88
Rated LLMF at 16,000 h 0.87
Luminous flux 2050 lm

Dimensions & weight

Tube diameter 26 mm
Length 1200 mm
Length with base excl. base pins/connection 1200.00 mm
Diameter 26.0 mm
Maximum diameter 26.0 mm

Temperatures & operating conditions

Rated ambient temp.w.max.luminous flux 25.0 °C

Lifespan

Service life
18000 h
Lifespan
20000 h
Rated lamp survival factor at 2,000 h 0.99
Rated lamp survival factor at 4,000 h 0.99
Rated lamp survival factor at 6,000 h 0.99
Rated lamp survival factor at 8,000 h 0.99
Rated lamp survival factor at 12,000 h 0.99
Rated lamp survival factor at 16,000 h 0.90
Operation mode LLMF/LSF HF
Rated lamp life time 20000 h
Nominal lamp life time 20000 h

Additional product data

Base (standard designation) G13
Mercury content 2.5 mg
Show WEEE picto Yes

Capabilities

Suitable for indoor Yes

Certificates & standards

Energy efficiency class B
Energy consumption 44 kWh/1000h
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4008321232724 UNV
1
1215mm x 25mm x 28mm 239.00g 0.85dm³
4008321232731 VS
12
1266mm x 202mm x 71mm 3147.00g 18.16dm³
EAN METEL code SEG number STK number EFO number ELDAS number
4008321232724 OSRL3662LUMLL 8329556 4932923 3830142 946115490
Product benefits
  • Excellent UV filter
Areas of application
  • Microchip fabrication plants
  • Where UV and blue components have to be reduced to the absolute minimum
  • Industry
Product features
  • Excellent filter at 500 nm
  • Long sleeve life (corresponds to the average life of the lamp)
  • Average lifetime: 20,000 h with preheat ECG
Equipment / Accessories
  • Suitable for use in open and enclosed luminaires

Safety advice
Lamps with plastic sleeves, ambient temperature range: -10…+80 °C
Lamps with plastic sleeves, maximum shelf life: 5 years at 0…30 °C
Lamps with plastic sleeves must be replaced after average lifetime (B50) has been reached
In case of lamp breakage: www.ledvance.com/brokenlamp
Under standard conditions acc. IEC (free burning, 25 - 40°C ambient temperature) a typical increase of the emitted radiation power in the wavelength range < 500 nm up to 3 mW/klm per 10,000 hours of operation was determined. This corresponds to approx. 0.1% of the total emitted radiation power. This increase depends on the operation conditions.
For example for a T5 HO lamp at 80°C ambient temperature an increase of the emitted radiation power in the wavelength range < 500 nm of up to 50 mW/klm per 10,000 hours of operation can be observed. This corresponds to approx. 2% of the total emitted radiation power.
For applications in photo sensitive areas, routine maintenance is necessary. This must include verification of the amount of short wavelength light emitted, and, if required, lamp replacement.

System guarantee
OSRAM System+ Guarantee in combination with OSRAM ECGs

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit www.ledvance.com/system-guarantee