Product description Dimmable Nominal wattage Color rendering index Ra Luminous flux at 25 °C Luminous flux at 35 °C
HO XT 49 W/840 Yes 49.00W ≥80 4300lm 4900lm
HO XT 49 W/865 Yes 49.00W ≥80 4100lm 4900lm
HO XT 54 W/840 Yes 54.00W ≥80 4450lm 5000lm
HO XT 54 W/865 Yes 54.00W ≥80 4100lm 5000lm
HO XT 80 W/840 Yes 80.00W ≥80 6150lm 7000lm
HO XT 80 W/865 Yes 80.00W ≥80 5700lm 6650lm
 

HO XT 80 W/840

Product benefits
  • Much lower total cost of ownership, comprising investment, maintenance and relamping costs
  • Lower maintenance costs thanks to longer replacement intervals
  • Longer service life, so fewer lamps for waste disposal
  • Compatible with and easily exchangeable with conventional T5 lamps
  • High luminous flux

Product details

Nominal current 0.76 A
Nominal wattage + Power loss 175.00 W
Luminous flux at 35 °C 6300 lm
Number of lighting outlets 2
Nominal current 0.39 A
Nominal wattage + Power loss 88.10 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 1
Nominal current 0.38 A
Nominal wattage + Power loss 85.00 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 1
Nominal current 0.74 A
Nominal wattage + Power loss 165.00 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 2
Nominal current 0.70 A
Nominal wattage + Power loss 167.00 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 2
Nominal current 0.39 A
Nominal wattage + Power loss 88.10 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 55 °C
ECG_2.2 Tc point temperature for lifespa 65 °C
ECG_2.3 Tc point temperature for lifespa 75 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 90000 h
Nominal current 0.74 A
Nominal wattage + Power loss 165.00 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 2
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 60 °C
ECG_2.2 Tc point temperature for lifespa 70 °C
ECG_2.3 Tc point temperature for lifespa 75 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 80000 h
Nominal current 0.38 A
Nominal wattage + Power loss 86.00 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 1

Electrical data

Nominal voltage 152 V
Rated lamp efficacy (HF data 25 °C) 77 lm/W
Rated wattage 79.80 W
Nominal wattage 80.00 W

Photometrical data

Color rendering index Ra ≥80
Rated luminous flux 6150 lm
Luminous flux at 25 °C 6150 lm
Luminous flux at 35 °C 7000 lm
Light color 840
Rated color temperature 4000 K
Nominal luminous flux 6150 lm
Light color (designation) LUMILUX Cool White
Rated LLMF at 2,000 h 0.95
Rated LLMF at 4,000 h 0.93
Rated LLMF at 6,000 h 0.92
Rated LLMF at 8,000 h 0.90
Rated LLMF at 12,000 h 0.90
Rated LLMF at 16,000 h 0.90
Rated LLMF at 20,000 h 0.89
Color temperature 4000 K
Luminous flux 6150 lm
Color rendering index Ra ≥80

Dimensions & weight

Tube diameter 16 mm
Length 1449 mm
Length with base excl. base pins/connection 1449.00 mm
Diameter 16.0 mm

Temperatures & operating conditions

Rated ambient temp.w.max.luminous flux 35.0 °C

Lifespan

Service life
30000 h
Lifespan
45000 h
Rated lamp survival factor at 2,000 h 0.99
Rated lamp survival factor at 4,000 h 0.99
Rated lamp survival factor at 6,000 h 0.99
Rated lamp survival factor at 8,000 h 0.99
Rated lamp survival factor at 12,000 h 0.99
Rated lamp survival factor at 16,000 h 0.99
Rated lamp survival factor at 20,000 h 0.98
Operation mode LLMF/LSF HF
Rated lamp life time 45000 h
Nominal lamp life time 45000 h

Additional product data

Base (standard designation) G5
Mercury content 2.5 mg
Show WEEE picto Yes
Product remark For ECG operation only/Lamp designed for internal luminaire temperatures of 30…40 °C; optimum luminous flux achieved at 35 °C

Capabilities

Dimmable Yes
Suitable for indoor Yes

Certificates & standards

Energy efficiency class A
Energy consumption 88 kWh/1000h
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4008321958594 FLH
1
1470mm x 20mm x 20mm 159.00g 0.59dm³
4008321958716 VS
20
1482mm x 83mm x 104mm 3450.00g 12.79dm³
EAN SEG number STK number ELDAS number
4008321958594 8328789 4930073 946109220
Product benefits
  • Much lower total cost of ownership, comprising investment, maintenance and relamping costs
  • Lower maintenance costs thanks to longer replacement intervals
  • Longer service life, so fewer lamps for waste disposal
  • Compatible with and easily exchangeable with conventional T5 lamps
  • High luminous flux
Areas of application
  • Industry
  • Tunnels, underpasses
Product features
  • Extremely reliable: long life, low premature failure rate, 90 % luminous flux throughout their life
  • Extremely long average lifetime: up to 45,000 h (with QUICKTRONIC ECG)
  • Good color rendering group: 1B (Ra: 80…89)
  • Dimmable

Safety advice
In case of lamp breakage: www.ledvance.com/brokenlamp

System guarantee
OSRAM System+ Guarantee in combination with OSRAM ECGs

References / Links