Professional
Country

OSRAM DULUX L LUMILUX

Choose your product version

Overview OSRAM DULUX L LUMILUX

Product description Nominal voltage Nominal luminous flux Diameter Overall length Burning position
DULUX L 18 W/827 2G11 57V 1200lm 17.5mm 214.5mm
DULUX L 18 W/830 2G11 57V 1200lm 17.5mm 214.5mm
DULUX L 18 W/840 2G11 57V 1200lm 17.5mm 214.5mm
DULUX L 24 W/827 2G11 1800lm 17.5mm 314.5mm
DULUX L 24 W/830 2G11 87V 1800lm 17.5mm 314.5mm
DULUX L 24 W/840 2G11 1800lm 17.5mm 314.5mm
DULUX L 36 W/827 2G11 102V 2900lm 17.5mm 408.5mm
DULUX L 36 W/830 2G11 102V 2900lm 17.5mm 408.5mm
DULUX L 36 W/835 2G11 2900lm 16.0mm 408.5mm
DULUX L 36 W/840 2G11 102V 2900lm 17.5mm 408.5mm
DULUX L 36 W/865 2G11 2755lm 17.5mm 408.5mm
DULUX L 40 W/830 2G11 3500lm 17.5mm 530.5mm
DULUX L 40 W/840 2G11 3500lm 17.5mm 530.5mm
DULUX L 40 W/865 2G11 3325lm 17.5mm 530.5mm
DULUX L 55 W/827 2G11 101V 4800lm 17.5mm 530.5mm
DULUX L 55 W/830 2G11 4800lm 17.5mm 530.5mm
DULUX L 55 W/835 2G11 101V 4800lm 18.0mm 530.5mm
DULUX L 55 W/840 2G11 101V 4800lm 17.5mm 530.5mm
DULUX L 55 W/865 2G11 4550lm 17.5mm 530.5mm
DULUX L 80 W/830 2G11 6000lm 17.5mm 562.5mm
DULUX L 80 W/840 2G11 6000lm 17.5mm 562.5mm
 

DULUX L 36 W/840 2G11

Product benefits
  • Very economical
  • Outstanding luminous flux
  • Outstanding luminous efficiency
  • Long service life
  • OSRAM System+ Guarantee in combination with OSRAM QUICKTRONIC ECG
  • Less than half as long as tubular fluorescent lamps
  • Improved maintenance

Product details

Nominal current 0.16 A
Nominal wattage + Power loss 36.00 W
Luminous flux at 35 °C 3350 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 50 °C
ECG_2.2 Tc point temperature for lifespa 60 °C
ECG_2.3 Tc point temperature for lifespa 70 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 100000 h
Nominal current 0.32 A
Nominal wattage + Power loss 72.40 W
Luminous flux at 35 °C 3350 lm
Number of lighting outlets 2
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 55 °C
ECG_2.2 Tc point temperature for lifespa 65 °C
ECG_2.3 Tc point temperature for lifespa 75 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 90000 h
Nominal current 0.15 A
Nominal wattage + Power loss 34.00 W
Luminous flux at 35 °C 2750 lm
Number of lighting outlets 1
Nominal current 0.29 A
Nominal wattage + Power loss 68.00 W
Luminous flux at 35 °C 2800 lm
Number of lighting outlets 2
Nominal current 0.16 A
Nominal wattage + Power loss 36.00 W
Luminous flux at 35 °C 2900 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 50 °C
ECG_2.2 Tc point temperature for lifespa 60 °C
ECG_2.3 Tc point temperature for lifespa 70 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 100000 h
Nominal current 0.31 A
Nominal wattage + Power loss 69.00 W
Luminous flux at 35 °C 2900 lm
Number of lighting outlets 2
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 55 °C
ECG_2.2 Tc point temperature for lifespa 65 °C
ECG_2.3 Tc point temperature for lifespa 75 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 90000 h
Nominal current 0.30 A
Nominal wattage + Power loss 70.00 W
Luminous flux at 35 °C 2800 lm
Number of lighting outlets 2
Nominal current 0.33 A
Nominal wattage + Power loss 68.00 W
Luminous flux at 35 °C 2900 lm
Number of lighting outlets 2
Nominal current 0.16 A
Nominal wattage + Power loss 35.00 W
Luminous flux at 35 °C 2800 lm
Number of lighting outlets 1
Nominal current 0.30 A
Nominal wattage + Power loss 68.00 W
Luminous flux at 35 °C 2800 lm
Number of lighting outlets 2
Nominal current 0.16 A
Nominal wattage + Power loss 35.00 W
Luminous flux at 35 °C 2800 lm
Number of lighting outlets 1
Nominal current 0.30 A
Nominal wattage + Power loss 70.00 W
Luminous flux at 35 °C 2800 lm
Number of lighting outlets 2
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 55 °C
ECG_2.2 Tc point temperature for lifespa 60 °C
ECG_2.3 Tc point temperature for lifespa 70 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 70000 h

Electrical data

Nominal voltage 102 V
Rated wattage 36.00 W
Nominal wattage 36.00 W

Photometrical data

Nominal luminous flux 2900 lm
Luminous flux at 25 °C 2900 lm
Rated luminous flux 2900 lm
Rated color temperature 4000 K
Color rendering index Ra ≥80
Rated LLMF at 4,000 h 0.86
Rated LLMF at 6,000 h 0.82
Rated LLMF at 8,000 h 0.80
Rated LLMF at 12,000 h 0.76
Rated LLMF at 16,000 h 0.81
Rated LLMF at 20,000 h 0.80
Luminance 2.8 cd/cm²
Light color (designation) LUMILUX Cool White
Color temperature 4000 K
Luminous flux 2900 lm
Color rendering index Ra ≥80

Dimensions & weight

Diameter 17.5 mm
Overall length 408.5 mm
Tube diameter 17.5 mm
Length 411.0 mm
Length acc. to IEC standard 415 mm
Length with base excl. base pins/connection 411.00 mm
Outer bulb T16
Maximum diameter 17.0 mm

Temperatures & operating conditions

Rated ambient temp.w.max.luminous flux 25.0 °C

Lifespan

Nominal lamp life time 12000 h
Rated lamp life time 12000 h
Service life
13000 h
Rated lamp survival factor at 2,000 h 0.99
Rated lamp survival factor at 4,000 h 0.99
Rated lamp survival factor at 6,000 h 0.98
Rated lamp survival factor at 8,000 h 0.92
Rated lamp survival factor at 12,000 h 0.50
Rated lamp survival factor at 16,000 h 0.81
Rated lamp survival factor at 20,000 h 0.50
Operation mode LLMF/LSF HF
Lifespan
20000 h

Additional product data

Base (standard designation) 2G11
Mercury content 2.3 mg
Product remark For ECG and CCG operation

Capabilities

Dimmable Yes
Suitable for indoor Yes

Certificates & standards

Energy consumption 40 kWh/1000h
Energy efficiency class A

Country-specific categorizations

ILCOS FSD-36/840-E-2G11-43,9/411
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4050300010786 FS
1
442mm x 26mm x 46mm 380.75g 0.53dm³
4050300242224 VS
10
455mm x 119mm x 136mm 1410.00g 7.36dm³
EAN METEL code SEG number STK number EFO number ELDAS number
4050300010786 OSRDL36840 8330460 4933890 3820425 946167110
Product benefits
  • Very economical
  • Outstanding luminous flux
  • Outstanding luminous efficiency
  • Long service life
  • OSRAM System+ Guarantee in combination with OSRAM QUICKTRONIC ECG
  • Less than half as long as tubular fluorescent lamps
  • Improved maintenance
Areas of application
  • Offices, public buildings
  • Shops
  • Supermarkets and department stores
  • Hotels, restaurants
  • Industry
Product features
  • Short and compact pin-base lamp with double-turn tubes
  • Single-ended four-pin plug-in 2G11 base
  • Dimmable (1…100 % with QUICKTRONIC QTi DALI/DIM)
  • Color rendering index Ra: ≥ 80
  • Average life: 20,000 h (with QUICKTRONIC)
  • Operates on battery, solar and AC power with suitable electronic control gear
  • Also available in blue
Equipment / Accessories
  • Suitable for standard control gears and starters
  • Suitable for operation on electronic and conventional control gear

References / Links

For more information on the system guarantee and the terms and conditions of the guarantee visit www.ledvance.com/system-guarantee