Professional
Country

OSRAM DULUX D/E

Choose your product version

Overview OSRAM DULUX D/E

Product description Nominal voltage Nominal luminous flux Luminous intensity [PIM] Diameter Overall length
DULUX D/E 10 W/827 600lm 12.0mm 101.0mm
DULUX D/E 10 W/830 600lm 12.0mm 101.0mm
DULUX D/E 10 W/840 600lm 12.0mm 101.0mm
DULUX D/E 13 W/827 900lm 12.0mm 129.0mm
DULUX D/E 13 W/830 900lm 12.0mm 129.0mm
DULUX D/E 13 W/840 900lm 12.0mm 129.0mm
DULUX D/E 18 W/827 1200lm 12.0mm 144.0mm
DULUX D/E 18 W/830 1200lm 12.0mm 146.0mm
DULUX D/E 18 W/840 1200lm 12.0mm 144.0mm
DULUX D/E 18 W/865 1130lm 12.0mm 144.0mm
DULUX D/E 26 W/827 1710lm 12.0mm 169.5mm
DULUX D/E 26 W/830 1800lm 12.0mm 163.0mm
DULUX D/E 26 W/840 1800lm 12.0mm 163.0mm
DULUX D/E 26 W/865 1700lm 12.0mm 163.0mm
 

DULUX D/E 26 W/827

Product benefits
  • Extremly economical
  • Good quality of light
  • Excellent luminous flux
  • Long service life
  • Improved maintenance
  • OSRAM System+ Guarantee in combination with OSRAM QUICKTRONIC ECG

Product details

Nominal current 0.18 A
Nominal wattage + Power loss 23.50 W
Luminous flux at 25 °C 1600 lm
Number of lighting outlets 1
EEI – Energy Label A2 BAT
Nominal current 0.13 A
Nominal wattage + Power loss 29.00 W
Luminous flux at 25 °C 1800 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 55 °C
ECG_2.2 Tc point temperature for lifespa 65 °C
ECG_2.3 Tc point temperature for lifespa 75 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 90000 h
Nominal current 0.25 A
Nominal wattage + Power loss 56.00 W
Luminous flux at 25 °C 2*1800 lm
Number of lighting outlets 2
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 60 °C
ECG_2.2 Tc point temperature for lifespa 70 °C
ECG_2.3 Tc point temperature for lifespa 75 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 80000 h
Nominal current 0.13 A
Nominal wattage + Power loss 29.00 W
Luminous flux at 25 °C 1800 lm
Number of lighting outlets 1
Nominal current 0.25 A
Nominal wattage + Power loss 56.00 W
Luminous flux at 25 °C 2*1800 lm
Number of lighting outlets 2
Nominal current 0.23 A
Nominal wattage + Power loss 54.00 W
Luminous flux at 25 °C 2*1800 lm
Number of lighting outlets 2
Nominal current 0.12 A
Nominal wattage + Power loss 27.00 W
Luminous flux at 25 °C 1750 lm
Number of lighting outlets 1
Nominal current 0.24 A
Nominal wattage + Power loss 53.00 W
Luminous flux at 25 °C 2*1750 lm
Number of lighting outlets 2
Nominal current 0.13 A
Nominal wattage + Power loss 28.00 W
Luminous flux at 25 °C 1750 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 55 °C
ECG_2.2 Tc point temperature for lifespa 65 °C
ECG_2.3 Tc point temperature for lifespa 70 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 60000 h
Nominal current 0.24 A
Nominal wattage + Power loss 54.00 W
Luminous flux at 25 °C 2*1750 lm
Number of lighting outlets 2

Electrical data

Rated lamp efficacy (HF data 25 °C) Under clarification by authority and standardization body
Rated wattage 26.00 W
Nominal wattage 26.00 W

Photometrical data

Nominal luminous flux 1710 lm
Luminous flux at 25 °C 1800 lm
Rated luminous flux 1710 lm
Rated color temperature 2700 K
Color rendering index Ra ≥80
Rated LLMF at 2,000 h 0.90
Rated LLMF at 4,000 h 0.84
Rated LLMF at 6,000 h 0.83
Rated LLMF at 8,000 h 0.81
Rated LLMF at 12,000 h 0.79
Rated LLMF at 16,000 h 0.78
Rated LLMF at 20,000 h 0.77
Light color (designation) LUMILUX INTERNA
Color temperature 2700 K
Luminous flux 1710 lm
Color rendering index Ra ≥80

Dimensions & weight

Diameter 12.0 mm
Overall length 169.5 mm
Length 169.5 mm
Length acc. to IEC standard 160 mm
Length with base excl. base pins/connection 149.00 mm
Outer bulb T4
Maximum diameter 11.0 mm

Lifespan

Nominal lamp life time 10000 h
Rated lamp life time 10000 h
Service life
13000 h
Rated lamp survival factor at 2,000 h 0.99
Rated lamp survival factor at 4,000 h 0.99
Rated lamp survival factor at 6,000 h 0.99
Rated lamp survival factor at 8,000 h 0.99
Rated lamp survival factor at 12,000 h 0.95
Rated lamp survival factor at 16,000 h 0.81
Rated lamp survival factor at 20,000 h 0.50
Operation mode LLMF/LSF HF
Lifespan
20000 h

Additional product data

Base (standard designation) G24q-3
Mercury content 1.3 mg

Capabilities

Dimmable Yes
Suitable for indoor Yes

Certificates & standards

Energy consumption 29 kWh/1000h
Energy efficiency class A

Country-specific categorizations

ILCOS FSQH-26/827-/P/-G24q-3
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4050300012230 FS
1
179mm x 36mm x 36mm 59.00g 0.23dm³
4050300299594 VS
10
176mm x 194mm x 98mm 665.00g 3.35dm³
EAN METEL code SEG number STK number EFO number ELDAS number
4050300012230 OSRDDE26827 8330194 4933936 3820472 946157130
Product benefits
  • Extremly economical
  • Good quality of light
  • Excellent luminous flux
  • Long service life
  • Improved maintenance
  • OSRAM System+ Guarantee in combination with OSRAM QUICKTRONIC ECG
Areas of application
  • Offices, public buildings
  • Shops
  • Supermarkets and department stores
  • Hotels, restaurants
  • Industry
Product features
  • Average life: 20,000 h (with QUICKTRONIC)
  • Color rendering index Ra: ≥ 80
  • Dimmable (3…100 %)
  • Short and compact pin-base lamp with double-turn tubes
  • Single-ended four-pin plug-in G24q base
  • Operates on battery, solar and AC power with suitable electronic control gear
Equipment / Accessories
  • Suitable for operation on electronic control gear

Safety advice
In case of lamp breakage: www.ledvance.com/brokenlamp