Product description Lamp wattage Line current Ignition voltage Operating frequency Dimming interface
PTo 35/220…240 39W 0.20A 4.5kVp 0.165kHz
PTo 50/220…240 3DIM 50W 0.26A 4.5kVp 0.165kHz DALI
PTo 70/220…240 3DIM 73W 0.35A 4.5kVp 0.165kHz DALI
PTo 100/220…240 3DIM 97W 0.48A 4.5kVp 0.165kHz DALI
PTo 150/220…240 3DIM 147W 0.71A 4.5kVp 0.165kHz DALI
PTo 250/220…240 3DIM 250W 1.17A 4.5kVp 0.200…0.240kHz DALI
 

PTo 35/220…240

Product family benefits
  • Energy savings up to 30 % (compared to CCG operation) thanks to 3DIM (except PTo 35)
  • High surge protection: up to 3 kV (L-N) / 4 kV (L/N-PE)
  • Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
  • Excellent thermal behavior for very high limit temperatures tc and ta

Product details

Electrical data

Lamp wattage 39 W
Line current
0.20 A
Ignition voltage 4.5 kVp
Operating frequency 0.165 kHz
System wattage [AGGR] 43.00 W
ECG efficiency
90 %
Input voltage AC 198…264 V
Nominal voltage 220…240 V
Mains frequency 50…60 Hz
Power factor λ
0.95
Inrush current
35 A
Max. ECG no. on circuit breaker 10 A (B)
7
Max. ECG no. on circuit breaker 16 A (B)
13
Max. no. of ECGs on 16A MCB with EBN-OS
32
Protective conductor current 0.1 mA
U-OUT (working voltage) 250 V
Max. working voltage between LH and LL 250 V
Max. working voltage betw. LL/LH & earth 250 V
Max. capacitance of wire ECG/lamp 120 pF
Surge capability (L-N) 3 kV
Surge capability (L/N-Ground) 4 kV

Dimensions & weight

Length 133.0 mm
Width 77.0 mm
Height 48.0 mm
Mounting hole spacing, length 123.0 mm
Cable cross-section, input side 0.5…2.5 mm²
Cable cross-section, output side 0.5…2.5 mm²
Wire preparation length, input side 10…11 mm
Wire preparation length, output side 10…11 mm
Product weight 730.00 g

Colors & materials

Casing material Plastic

Temperatures & operating conditions

Ambient temperature range -25…+60 °C
Maximum temperature at tc test point 75 °C

Lifespan

ECG lifetime
60000 h

Additional product data

Required IP rating of luminaire ≥ 54
Design / version ECG outdoor
Encapsulated
Yes

Capabilities

Max. cable length to lamp/LED module 1.5 m
Overheating protection Power reduction and switch off at T > 75 °C at the tc point
ECG reset time > 0.5 s
Dimmable No
Restriction on ignition time 20 min
Suitable for fixtures with prot. class I / II
Lightning stroke protection With connected equipotentiality-terminal 10 surges with 10 kV acc. to IEC 61000-4-5

Certificates & standards

Approval marks – approval ENEC 10 / VDE / VDE-EMC / EAC / C-Tick
Type of protection IP20
EEI – Energy Label A2
Standards Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4008321956323 UNV
1
730.00g
4008321956330 VS
20
483mm x 167mm x 285mm 15471.00g 22.99dm³
EAN SEG number EFO number ELDAS number
4008321956323 7980340 6659855 919571600
Product family benefits
  • Energy savings up to 30 % (compared to CCG operation) thanks to 3DIM (except PTo 35)
  • High surge protection: up to 3 kV (L-N) / 4 kV (L/N-PE)
  • Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
  • Excellent thermal behavior for very high limit temperatures tc and ta
Areas of application
  • Suitable for luminaires of protection classes I and II
  • Suitable for outdoor applications in luminaires with IP > 54
Product family features
  • 3DIM functionality (StepDIM/AstroDIM/DALI)
  • Energy Efficiency Index EEI: A2
  • Lightning protection: up to 10 kV
  • Supply voltage: 220…240 V
  • Line frequency: 50…60 Hz
  • Line harmonics according to EN 61000-3-2
  • Immunity according to EN 61547
  • RI suppression: to EN 55015
  • Safety: to EN 61347-2-12
  • Luminous flux factor 1 compared with CCG operation
  • Not suitable for DC operation

Safety advice
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.
Attention!