Professional
Country

QUICKTRONIC INTELLIGENT

Choose your product version

Overview QUICKTRONIC INTELLIGENT

Product description Ambient temperature range Input voltage AC Nominal voltage Mains frequency Input voltage DC
QTi 1X14/24/21/39 GII -20…+50°C 198…264V 220…240V 50…60Hz 176…276V
QTi 1X28/54/35/49 GII -20…+50°C 198…264V 220…240V 50…60Hz 176…276V
QTi 1X35/49/80 GII -20…+50°C 198…264V 220…240V 50…60Hz 176…276V
QTi 2X14/24/21/39 GII -20…+50°C 198…264V 220…240V 50…60Hz 176…276V
QTi 2X28/54/35/49 GII -20…+50°C 198…264V 220…240V 50…60Hz 176…276V
QTi 2X35/49/80 GII -20…+50°C 198…264V 220…240V 50…60Hz 176…276V
 

QTi 1X35/49/80 GII

Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • VDE/VDE EMC certified system
  • Very high energy efficiency due to cut-off technology

Product details

Nominal current 0.26 A
Nominal wattage + Power loss 59.00 W
Luminous flux at 35 °C 4800 lm
Number of lighting outlets 1
Nominal current 0.38 A
Nominal wattage + Power loss 85.00 W
Luminous flux at 35 °C 6000 lm
Number of lighting outlets 1
Nominal current 0.26 A
Nominal wattage + Power loss 59.00 W
Luminous flux at 35 °C 4200 lm
Number of lighting outlets 1
Nominal current 0.08 A
Nominal wattage + Power loss 16.00 W
Luminous flux at 35 °C 1275 lm
Number of lighting outlets 1
Nominal current 0.11 A
Nominal wattage + Power loss 25.00 W
Luminous flux at 35 °C 1900 lm
Number of lighting outlets 1
Nominal current 0.15 A
Nominal wattage + Power loss 33.00 W
Luminous flux at 35 °C 2700 lm
Number of lighting outlets 1
Nominal current 0.17 A
Nominal wattage + Power loss 38.00 W
Luminous flux at 35 °C 3300 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 45 °C
ECG_2.2 Tc point temperature for lifespa 55 °C
ECG_2.3 Tc point temperature for lifespa 65 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 100000 h
Nominal current 0.24 A
Nominal wattage + Power loss 53.00 W
Luminous flux at 35 °C 4300 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 50 °C
ECG_2.2 Tc point temperature for lifespa 55 °C
ECG_2.3 Tc point temperature for lifespa 65 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 100000 h
Nominal current 0.38 A
Nominal wattage + Power loss 85.00 W
Luminous flux at 35 °C 6150 lm
Number of lighting outlets 1
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 50 °C
ECG_2.2 Tc point temperature for lifespa 55 °C
ECG_2.3 Tc point temperature for lifespa 70 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 60000 h

Electrical data

Input voltage AC 198…264 V
Nominal voltage 220…240 V
Mains frequency 50…60 Hz
Input voltage DC 176…276 V
Operating frequency 42…85 kHz
Max. ECG no. on circuit breaker 10 A (B)
8
Max. ECG no. on circuit breaker 16 A (B)
13
Inrush current 53 A

Light technical data

Starting time 1.0 s

Dimensions & weight

Length 360.0 mm
Width 30.0 mm
Height 21.0 mm
Mounting hole spacing, length 350.0 mm
Product weight 240.00 g

Temperatures & operating conditions

Ambient temperature range -20…+50 °C
Permitted rel. humidity during operation
5…85 %

Lifespan

ECG lifetime
100000 h

Capabilities

Suitable for emergency lighting Yes
Suitable for fixtures with prot. class I / II
End of lamp life safety shutdown EOL T.2

Certificates & standards

Approval marks – approval VDE / VDE-EMC / ENEC 10 / CE
EEI – Energy Label A2 BAT
Standards Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547
Protection class II
Type of protection IP20
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4008321383372 UNV
1
240.00g
4008321383389 VS
20
392mm x 98mm x 165mm 5019.99g 6.34dm³
EAN METEL code SEG number STK number EFO number ELDAS number
4008321383372 OSRQTI1X3580N 7980334 4030506 6659848 919481950
Product family benefits
  • Long lamp life
  • No adverse effect from frequent on/off switching
  • Automatic restart after lamp replacement
  • Perfect lamp start for applications with motion sensors
  • VDE/VDE EMC certified system
  • Very high energy efficiency due to cut-off technology
Areas of application
  • Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Sports halls and factories
  • Strip lighting
  • Suitable for emergency lighting (DC operation)
  • Modernization of existing systems
  • Suitable for luminaires of protection classes I and II
Product family features
  • Supply voltage: 220…240 V
  • Line voltage: 198…264 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Lamp start with optimum filament preheating
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Energy Efficiency Index EEI: A2 BAT
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Safety: to EN 61347-2-3
  • Lamp operation: to EN 60929