Professional
Country

QUICKTRONIC INTELLIGENT DALI DIM T8

Choose your product version

Overview QUICKTRONIC INTELLIGENT DALI DIM T8

Product description Ambient temperature range Input voltage AC Nominal voltage Mains frequency Input voltage DC
QTi DALI 1X18 DIM -20…+50°C 198…264V 220…240V 50…60Hz 154…276V
QTi DALI 1X36 DIM -20…+50°C 198…264V 220…240V 50…60Hz 154…276V
QTi DALI 1X58 DIM -20…+50°C 198…264V 220…240V 50…60Hz 154…276V
QTi DALI 2X18 DIM -20…+50°C 198…264V 220…240V 50…60Hz 154…276V
QTi DALI 2X36 DIM -20…+50°C 198…264V 220…240V 50…60Hz 154…276V
QTi DALI 2X58 DIM -20…+50°C 198…264V 220…240V 50…60Hz 154…276V
QTi DALI 3X18 DIM 0…+50°C 198…264V 220…240V 50…60Hz 154…276V
QTi DALI 4X18 DIM 0…+50°C 198…264V 220…240V 50…60Hz 154…276V
 

QTi DALI 2X18 DIM

Product family benefits
  • System+ Guarantee available
  • Easy integration in luminaire thanks to same dimensions like DALI GI ECG
  • TouchDIM function for easy and inexpensive dimming of several ECGs
  • Same luminous flux with direct and alternating current
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Automatic restart after lamp replacement
DALI product features
  • Control via the DALI interface
  • Compliance with the DALI Version-1 and IEC 60929
  • Control input protected against overvoltage and polarity reversal (OSRAM ECG)
Touch DIM and Touch DIM Sensor function
  • Manual dimming without controller and with standard switches
  • Including memory function (double click) and soft start

Product details

Nominal current 0.16 A
Nominal wattage + Power loss 37.00 W
Luminous flux at 35 °C 1100 lm
Number of lighting outlets 2
Nominal current 0.16 A
Nominal wattage + Power loss 37.00 W
Luminous flux at 35 °C 1200 lm
Number of lighting outlets 2
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 50 °C
ECG_2.2 Tc point temperature for lifespa 60 °C
ECG_2.3 Tc point temperature for lifespa 70 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 100000 h
Nominal current 0.16 A
Nominal wattage + Power loss 36.50 W
Luminous flux at 35 °C 1350 lm
Number of lighting outlets 2
ECG_1.1 Ambient temperature for lifespan 40 °C
ECG_1.2 Ambient temperature for lifespan 50 °C
ECG_1.3 Ambient temperature for lifespan 60 °C
ECG_2.1 Tc point temperature for lifespa 50 °C
ECG_2.2 Tc point temperature for lifespa 60 °C
ECG_2.3 Tc point temperature for lifespa 70 °C
ECG_3.1 Temperature dependent lifespan 100000 h
ECG_3.2 Temperature dependent lifespan 100000 h
ECG_3.3 Temperature dependent lifespan 100000 h
Nominal current 0.16 A
Nominal wattage + Power loss 36.50 W
Luminous flux at 35 °C 1350 lm
Number of lighting outlets 2
Nominal current 0.16 A
Nominal wattage + Power loss 36.50 W
Luminous flux at 35 °C 1350 lm
Number of lighting outlets 2

Electrical data

Input voltage AC 198…264 V
Nominal voltage 220…240 V
Mains frequency 50…60 Hz
Input voltage DC 154…276 V
Operating frequency 51…120 kHz
Max. ECG no. on circuit breaker 10 A (B)
12
Max. ECG no. on circuit breaker 16 A (B)
19
Power loss in stand-by mode 0.2 W
Inrush current 35 A

Light technical data

Starting time 0.6 s

Dimensions & weight

Length 423.0 mm
Width 30.0 mm
Height 21.0 mm
Mounting hole spacing, length 415.0 mm
Product weight 370.00 g
Wire preparation length, input side
8.0…9.0 mm
Wire preparation length, output side
8.0…9.0 mm
Cable cross-section, output side
0.5…1.5 / 0.5…1.0 mm²
Cable cross-section, input side
0.5…1.5 / 0.5…1.0 mm²

Temperatures & operating conditions

Ambient temperature range -20…+50 °C
Permitted rel. humidity during operation
5…85 %

Lifespan

ECG lifetime
100000 h

Capabilities

Dimming interface DALI / Touch DIM / Touch DIM Sensor
Dimming range
1…100 %
Dimmable Yes
Overload protection Yes
Overheating protection Power reduction and switch off at T > 75 °C at the tc point
Suitable for fixtures with prot. class I
End of lamp life safety shutdown EOL T.2

Certificates & standards

Approval marks – approval VDE / VDE-EMC / EL / EAC / RCM / CCC
Standards Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547/Acc. to IEC 62386-101:Ed1/Acc. to IEC 62386-102:Ed1
EEI – Energy Label A1 BAT
Protection class I
Type of protection IP20
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4050300870526 UNV
1
370.00g
4050300870533 VS
20
455mm x 98mm x 163mm 7640.00g 7.27dm³
EAN METEL code SEG number EFO number ELDAS number
4050300870526 OSRQTIDALI2X18 7980237 3322115 919484320
Product family benefits
  • System+ Guarantee available
  • Easy integration in luminaire thanks to same dimensions like DALI GI ECG
  • TouchDIM function for easy and inexpensive dimming of several ECGs
  • Same luminous flux with direct and alternating current
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Automatic restart after lamp replacement
DALI product features
  • Control via the DALI interface
  • Compliance with the DALI Version-1 and IEC 60929
  • Control input protected against overvoltage and polarity reversal (OSRAM ECG)
Touch DIM and Touch DIM Sensor function
  • Manual dimming without controller and with standard switches
  • Including memory function (double click) and soft start
Areas of application
  • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
  • Installation in emergency lighting systems according to IEC 61347-2-3, appendix J
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Sports halls and factories
  • Strip lighting
  • Suitable for luminaires of protection class I
Product family features
  • Corridor function for direct connection of ECG to common motion sensor
  • Corridor function with pre-programmed light program
  • Touch DIM function for free parameterization of light value and turn on time
  • Fit for SMART GRID for feedback of consumed mains power and lamp operating hours
  • Fit for emergency function for automatic detection of emergency lighting by ECG
  • Very low standby power consumption: < 0.2 W (A1 BAT)
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Very high number of switching cycles: up to 300,000
  • Dimming range: 1…100 % (3…100 % with compact fluorescent lamp)
  • POWER2LAMP function for optimal matching of ECG power to lamp during lamp lifetime
  • Line frequency: 0 Hz, 50…60 Hz, rectified AC

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit www.ledvance.com/system-guarantee