QUICKTRONIC INTELLIGENT DIM T8

Choose your product version

Overview QUICKTRONIC INTELLIGENT DIM T8

Product description Ambient temperature range Input voltage AC Nominal voltage Mains frequency Input voltage DC
QTi 3X18 DIM -20…+50°C 198…264V 220…240V 50/60Hz 154…276V
QTi 4X18 DIM -20…+50°C 198…264V 220…240V 50…60Hz 154…276V
 

QTi 4X18 DIM

Product family benefits
  • Same luminous flux with direct and alternating current
  • Perfect lamp start for applications with motion sensors
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Very high efficiency thanks to cut-off technology
  • Automatic restart after lamp replacement
  • ECGs comply with MINERGIE standard due to very low standby consumption
  • Configurable emergency power characteristics
  • Control via the 1…10 V interface

Product details

Nominal current 0.31 A
Nominal wattage + Power loss 69.30 W
Luminous flux at 35 °C 1100 lm
Number of lighting outlets 4
Nominal current 0.31 A
Nominal wattage + Power loss 69.30 W
Luminous flux at 35 °C 1200 lm
Number of lighting outlets 4
Nominal current 0.31 A
Nominal wattage + Power loss 69.30 W
Luminous flux at 35 °C 1350 lm
Number of lighting outlets 4
Nominal current 0.31 A
Nominal wattage + Power loss 69.30 W
Luminous flux at 35 °C 1350 lm
Number of lighting outlets 4
Nominal current 0.31 A
Nominal wattage + Power loss 69.30 W
Luminous flux at 35 °C 1350 lm
Number of lighting outlets 4

Electrical data

Input voltage AC 198…264 V
Nominal voltage 220…240 V
Mains frequency 50…60 Hz
Input voltage DC 154…276 V
Operating frequency 40…100 kHz
Max. ECG no. on circuit breaker 10 A (B)
12
Max. ECG no. on circuit breaker 16 A (B)
19
Inrush current 35 A

Light technical data

Starting time 0.6 s

Dimensions & weight

Length 360.0 mm
Width 40.0 mm
Height 21.0 mm
Mounting hole spacing, length 350.0 mm
Product weight 401.00 g
Wire preparation length, input side
8.0…9.0 mm
Wire preparation length, output side
8.0…9.0 mm
Cable cross-section, output side
0.5…1.5 / 0.5…1.0 mm²
Cable cross-section, input side
0.5…1.5 / 0.5…1.0 mm²

Temperatures & operating conditions

Ambient temperature range -20…+50 °C
Permitted rel. humidity during operation
5…85 %

Lifespan

ECG lifetime
100000 h

Capabilities

Dimming interface 1…10 V
Dimming range
1…100 %
Dimmable Yes
Overload protection Automatic switch off, reversible
Overheating protection Power reduction and switch off at T > 75 °C at the tc point
Suitable for fixtures with prot. class I
End of lamp life safety shutdown EOL T.2

Certificates & standards

Approval marks – approval VDE / VDE-EMC / EAC / CCC
Standards Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547
EEI – Energy Label A1 BAT
Protection class I
Type of protection IP20
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4008321070012 UNV
1
401.00g
4008321070029 VS
20
384mm x 90mm x 210mm 8292.00g 7.26dm³
EAN METEL code SEG number STK number EFO number ELDAS number
4008321070012 OSRQTI4X18DIM 7980263 4031122 3322252 919483500
Product family benefits
  • Same luminous flux with direct and alternating current
  • Perfect lamp start for applications with motion sensors
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Very high efficiency thanks to cut-off technology
  • Automatic restart after lamp replacement
  • ECGs comply with MINERGIE standard due to very low standby consumption
  • Configurable emergency power characteristics
  • Control via the 1…10 V interface
Areas of application
  • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
  • Installation in emergency lighting systems according to IEC 61347-2-3, appendix J
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Suitable for luminaires of protection class I
Product family features
  • Control via 1…10 V interface
  • Supply voltage: 220…240 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Line voltage: 198…264 V
  • Dimming range: 1…100 % luminous flux
  • Lamp start: within 0.6 s
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Energy Efficiency Index EEI: A1 BAT
  • Overtemperature protection: Thermal management at high tc temperatures
  • Safety: to EN 61347-2-3
  • Lamp operation: to EN 60929
  • RI suppression: to EN 55015:2006+A1:2007+A2:2009/CISPR 15
  • Line harmonics according to EN 61000-3-2
  • Immunity according to EN 61547