Product description | Nominal voltage | Input voltage AC | Mains frequency | Power factor λ | Device power loss |
---|---|---|---|---|---|
OT 20/170 240/1A0 4DIMLT2 G2 CE | 220 240V | 170 264V | 50 60Hz | > 0.98 | 3.5W |
OT 40/120 277/1A0 4DIMLT2 E | 120 277V | 108 305V | 50 60Hz | 0.95/0.90 | 6.5W |
OT 40/170 240/1A0 4DIMLT2 G2 CE | 220 240V | 170 264V | 50 60Hz | > 0.98 | 4.5W |
OT 60/170 240/1A0 4DIMLT2 E | 220 240V | 170 264V | 50 60Hz | 0.95/0.90 | 7.4W |
OT 75/170 240/1A0 4DIMLT2 G2 CE | 220 240V | 170 240V | 50/60Hz | > 0.98 | 5.3W |
OT 90/170 240/1A0 4DIMLT2 E | 220 240V | 170 264V | 50 60Hz | 0.95/0.90 | 9.6W |
OT 110/170 240/1A0 4DIMLT2 G2 CE | 220 240V | 170 240V | 50/60Hz | > 0.98 | 8.0W |
OT 165/170 240/1A0 4DIMLT2 E | 220 240V | 170 264V | 50 60Hz | 0.95/0.90 | 13W |
Nominal voltage | 220 240 V |
Input voltage AC | 170 264 V |
Nominal current | 0.12 A |
Mains frequency | 50 60 Hz |
Nominal input voltage (SD port) | 220 277 V |
Power factor λ | > 0.98 |
Total harmonic distortion |
< 10 %
|
Device power loss | 3.5 W |
Inrush current |
25 A
|
Max. ECG no. on circuit breaker 10 A (B) | 22 |
Max. ECG no. on circuit breaker 16 A (B) | 35 |
Max. ECG no. on circuit breaker 25 A (B) | 55 |
Max. no. of ECGs on 16A MCB with EBN-OS | 93 |
Surge capability (L/N-Ground) | 10 kV |
Surge capability (L-N) | 6 kV |
Surge capability (L/N – SD) | 6 kV |
Surge capability (SD – Ground) | 10 kV |
Nominal output power | 22 W |
ECG efficiency | 87 % |
Nominal output voltage | 10 38 V |
U-OUT (working voltage) | 60 V |
Nominal output current | 200 1050 mA |
Output current tolerance | ±3 % |
Output ripple current (100 Hz) | < 5 % |
Minimum output current | 70 mA |
Galvanic isolation | SELV |
Length | 123.0 mm |
Width | 79.0 mm |
Height | 33.0 mm |
Mounting hole spacing, length | 111.0 mm |
Mounting hole spacing, width | 67.0 mm |
Product weight | 210.00 g |
Cable cross-section, input side | 0.2 1.5 mm² |
Cable cross-section, output side | 0.2 1.5 mm² |
Wire preparation length, input side | 8.5 9.5 mm |
Ambient temperature range | -40 +60 °C |
Maximum temperature at tc test point | 75 °C |
Max.housing temperature in case of fault | 120 °C |
Permitted rel. humidity during operation |
5
85 %
|
ECG lifetime |
50000 / 100000 h
|
Dimmable | Yes |
Dimming interface | 4DIM / AstroDIM / DALI / MainsDIM / StepDIM |
Dimming range | 10 100 % |
Suitable for fixtures with prot. class | I / II |
Constant lumen function | Programmable |
NTC input | Yes |
Overheating protection | Automatic reversible |
Overload protection | Automatic reversible |
Short-circuit protection | Automatic reversible |
No-load proof | Yes |
Max. cable length to lamp/LED module | 2.0 m |
Type of protection | IP20 |
Standards | Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN 55015:2006 + A1:2007 + A2:2009/Acc. to EN 61547/Acc. to FCC 47 part 15 class B/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/Acc. to IEC 62386-101/Acc. to IEC 62386-102/Acc. to IEC 62386-207/UL-8750 |
Approval marks – approval | CE / ENEC / VDE / VDE-EMC / CCC / EL / RCM |
Temperature range at storage | -25 85 °C |
Product code | Packaging unit Piece / unit |
Dimensions in h x w x l | Gross weight | Volume |
---|---|---|---|---|
4052899981928 | UNV 1 |
|||
4052899982017 | VS 20 |