Professional
Country

OT 2DIM IP64 Outdoor

Choose your product version

Overview OT 2DIM IP64 Outdoor

Product description Nominal voltage Input voltage AC Mains frequency Power factor λ Device power loss
OT 50/120…277/800 2DIMLT2 P 120…277V 108…305V 50…60Hz 0.95/0.90 10W
OT 50/120…277/1A2 2DIMLT2 P 120…277V 108…305V 50…60Hz 0.95/0.90 9.6W
OT 100/120…277/800 2DIMLT2 P 120…277V 108…305V 50…60Hz 0.95/0.90 14W
OT 110/120…277/1A4 2DIMLT2 P 120…277V 108…305V 50…60Hz 0.95/0.90 15.0W
 

OT 100/120…277/800 2DIMLT2 P

Product family benefits
  • 2DIM functionality in one device (AstroDIM, 0…10 V)
  • High surge protection: up to 6 kV (in protection class I or II)
  • Fast programming without mains voltage
  • High efficiency
  • Great flexibility due to wide operating temperature range of -40…55 °C
  • Protection through double isolation between mains input and LED output
  • IP rating: IP64

Product details

Electrical data

Nominal voltage 120…277 V
Input voltage AC
108…305 V
Nominal current 0.49 A
Mains frequency 50…60 Hz
Power factor λ
0.95/0.90
Total harmonic distortion
15 %
Device power loss
14 W
Inrush current
55 A
Max. ECG no. on circuit breaker 10 A (B)
6
Max. ECG no. on circuit breaker 16 A (B)
10
Max. ECG no. on circuit breaker 25 A (B)
16
Surge capability (L/N-Ground)
6 kV
Surge capability (L-N)
6 kV
Nominal output power
100 W
ECG efficiency
90 %
Nominal output voltage 50…186 V
U-OUT (working voltage) 200 V
Nominal output current 350…800 mA
Output current tolerance ±5 %
Output ripple current (100 Hz) 25 %
Minimum output current 105 mA
Galvanic isolation double/reinforced

Dimensions & weight

Length 168.0 mm
Width 68.0 mm
Height 38.0 mm
Mounting hole spacing, length 152.0 mm
Product weight 740.00 g
Cable/wire length, output side
280 mm
Cable/wire length, input side
300 mm
Cable/wire length, control input
280 mm

Temperatures & operating conditions

Ambient temperature range -40…+55 °C
Maximum temperature at tc test point
85 °C
Max.housing temperature in case of fault 120 °C
Permitted rel. humidity during operation
5…85 %

Lifespan

ECG lifetime
80000 h

Capabilities

Dimmable Yes
Dimming interface 2DIM / 1…10 V / AstroDIM
Dimming range 30…100 %
Suitable for fixtures with prot. class I / II
Constant lumen function Programmable
NTC input
Yes
Overheating protection Yes
Overload protection Automatic reversible
Short-circuit protection Yes
No-load proof Yes
Max. cable length to lamp/LED module 10 m
Cable/wire types, output side
AWG 18, solid
Cable/wire types, input side
AWG 18, solid
Cable/wire types, control input
AWG 18, solid

Certificates & standards

Type of protection IP64
Standards Acc. to EN 61347/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN 55015:2006 + A1:2007 + A2:2009/Acc. to EN 61547/Acc. to FCC 47 part 15 class A/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/UL-8750
Approval marks – approval CE / ENEC 15 / UR / CQC

Logistical data

Temperature range at storage -25…80 °C
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4052899253414 UNV
1
740.00g
4052899253421 VS
20
358mm x 188mm x 220mm 15346.00g 14.81dm³
EAN EFO number
4052899253414 6608507
Product family benefits
  • 2DIM functionality in one device (AstroDIM, 0…10 V)
  • High surge protection: up to 6 kV (in protection class I or II)
  • Fast programming without mains voltage
  • High efficiency
  • Great flexibility due to wide operating temperature range of -40…55 °C
  • Protection through double isolation between mains input and LED output
  • IP rating: IP64
Areas of application
  • Street and urban lighting
  • Industry
  • Suitable for luminaires of protection classes I and II
Product family features
  • Available with different wattage: 50 W, 100 W, 110 W
  • Input voltage: 120…277 V
  • Available with output current range: up to 1,400 mA
  • Flexible current setting with one additional wire (LEDset2)
  • AstroDIM for autonomous dimming with five independent levels (astro mode)
  • Isolated 0…10 V interface for unidirectional telemanagement systems
  • Constant Lumen Output (CLO)
  • Overtemperature protection with external NTC or LEDset2 interface
Equipment / Accessories
  • OT Programmer hardware for configuration of 2DIM ECGs necessary
  • Programmable via Tuner4TRONIC software