Product description | Length | Width | Height | Product weight | Prewired |
---|---|---|---|---|---|
OTi DALI 35/220 240/700 LT2 L G2 | 360.0mm | 30.0mm | 21.0mm | 240.00g | |
OTi DALI 50/220 240/1A4 LT2 L G2 | 360.0mm | 30.0mm | 21.0mm | 240.00g | |
OTi DALI 35/220 240/700 LT2 L | 360.0mm | 30.0mm | 21.0mm | 275.00g | |
OTi DALI 80/220 240/1A6 LT2 L | 360.0mm | 30.0mm | 21.0mm | 285.00g | |
OTi DALI 80/220 240/2A1 LT2 L | 360.0mm | 30.0mm | 21.0mm | 285.00g | |
OTi DALI 90/220 240/1A0 LT2 L | 280.0mm | 30.0mm | 21.0mm | 205.00g | |
OTi DALI 90/220 240/700 D LT2 L | 280.0mm | 30.0mm | 21.0mm | 205.00g | |
OTi DALI 60/220 240/550 D LT2 L | 280.0mm | 30.0mm | 21.0mm | 205.00g | |
OTi DALI 35/220-240/400 D LT2 L | 280.0mm | 30.0mm | 21.0mm | 205.00g |
Nominal voltage | 220 240 V |
Mains frequency | 50 60 Hz |
Input voltage AC |
198
264 V
|
Input voltage DC | 176 276 V |
Total harmonic distortion | < 20 % |
Power factor λ |
> 0.95
|
ECG efficiency |
≧90 %
|
Device power loss |
8.5 W
|
Power loss in stand-by mode | <0.5 W |
Protective conductor current | <2.0 mA |
Inrush current |
53 A
|
Max. ECG no. on circuit breaker 10 A (B) | 8 |
Max. ECG no. on circuit breaker 16 A (B) | 13 |
Max. ECG no. on circuit breaker 25 A (B) | - |
Surge capability (L/N-Ground) | 2 kV |
Surge capability (L-N) | 1 kV |
Nominal output voltage |
20
54 V
|
U-OUT (working voltage) | < 60 V |
Nominal output current |
600
1550 mA
|
Output current tolerance | ±3 % |
Output ripple current (100 Hz) | < 1 % |
Nominal output power | 32 80 W |
Galvanic isolation | SELV |
Galvanic isolation primary/secondary |
3.75 kV
|
Length | 360.0 mm |
Width | 30.0 mm |
Height | 21.0 mm |
Mounting hole spacing, length | 350.0 mm |
Cable cross-section, input side |
0.5
1.5 mm²
|
Cable cross-section, output side |
0.5
1.5 mm²
|
Product weight | 285.00 g |
Wire preparation length, input side | 8.5 9.5 mm |
Wire preparation length, output side | 8.5 9.5 mm |
Casing material | Metal |
Ambient temperature range | -25 +50 °C |
Maximum temperature at tc test point | 80 °C |
Max.housing temperature in case of fault | 120 °C |
Permitted rel. humidity during operation |
5
85 %
|
ECG lifetime |
50000 / 100000 h
|
Encapsulated | No |
Dimmable | Yes |
Dimming interface | DALI / Touch DIM / Touch DIM Sensor |
Dimming range |
1
100 %
|
Dimming method | Amplitude Modulation / Pulse Width Modulation |
Constant lumen function | Programmable |
Overheating protection | Automatic reversible |
Overload protection | Automatic reversible |
Short-circuit protection | Automatic reversible |
No-load proof | Yes |
Max. cable length to lamp/LED module | 2.0 m |
Suitable for fixtures with prot. class | I |
Suitable for emergency lighting | Yes |
Type of connection, output side | Push terminal |
Approval marks – approval | CE / EL / ENEC 10 / VDE-EMC / CCC / RCM |
Standards | Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 55015/Acc. to EN 61547/Acc. to EN 61000-3-2/Acc. to EN 62384 |
Type of protection | IP20 |
Temperature range at storage | -25 85 °C |
Product code | Packaging unit Piece / unit |
Gross weight | Volume | |
---|---|---|---|---|
4052899028074 | UNV 1 |
285.00g | ||
4052899028081 | VS 20 |
385mm x 160mm x 100mm | 5871.00g | 6.16dm³ |
EAN | EFO number | ELDAS number |
---|---|---|
4052899028074 | 6615943 | 941795400 |