Product description | Nominal voltage | Length | Width | Height | Mounting hole spacing, length |
---|---|---|---|---|---|
DR PC-PFM -13/220-240/350 | 220 240V | 97.0mm | 43.0mm | 30.0mm | 88.0mm |
DR PC-PFM -18/220-240/350 | 220 240V | 130.0mm | 43.0mm | 30.0mm | 121.0mm |
DR PC-PFM -25/220-240/700 | 220 240V | 130.0mm | 43.0mm | 30.0mm | 121.0mm |
DR PC-PFM -35/220-240/700 | 220 240V | 150.0mm | 43.0mm | 30.0mm | 141.0mm |
Nominal voltage | 220 240 V |
Mains frequency | 50/60 Hz |
Input voltage AC |
198
264 V
|
Total harmonic distortion |
18 %
|
Power factor λ |
0.95
|
ECG efficiency |
79 %
|
Device power loss |
2.6 W
|
Inrush current |
5 A
|
Max. ECG no. on circuit breaker 10 A (B) | 81 |
Max. ECG no. on circuit breaker 16 A (B) | 130 |
Max. ECG no. on circuit breaker 25 A (B) | 203 |
Surge capability (L-N) | 0.5 kV |
Nominal output voltage |
17
36 V
|
U-OUT (working voltage) | 60 V |
Nominal output current |
350 mA
|
Output current tolerance | ±5 % |
Output ripple current (100 Hz) | < 5 % |
Nominal output power |
13 W
|
Galvanic isolation | SELV |
Galvanic isolation primary/secondary | 3.75 kV |
Length | 97.0 mm |
Width | 43.0 mm |
Height | 30.0 mm |
Mounting hole spacing, length | 88.0 mm |
Mounting hole spacing, width | 34.0 mm |
Cable cross-section, input side | 0.75 1.5 mm² |
Cable cross-section, output side | 0.5 1.5 mm² |
Product weight | 98.00 g |
Wire preparation length, input side | 8.0 mm |
Wire preparation length, output side | 8.0 mm |
Prewired | No |
Body material | Plastic |
Ambient temperature range | -20 +50 °C |
Maximum temperature at tc test point | 75 °C |
Max.housing temperature in case of fault | 95 °C |
Permitted rel. humidity during operation |
10
90 %
|
ECG lifetime |
50000 h
|
Encapsulated | No |
Dimmable | Yes |
Dimming interface | Phase Cut |
Dimming range | 10 100 % |
Dimming method | Trailing- or leading-edge phase control |
Overheating protection | false |
Overload protection | Yes |
Short-circuit protection | Yes |
Max. cable length to lamp/LED module | 2.0 m |
Suitable for fixtures with prot. class | I / II |
Type of connection, output side | Push terminal |
Suitable for no-load mode operation | Yes |
Approval marks – approval | TUV / CE |
Standards | Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 55015/Acc. to EN 61547/Acc. to EN 61000-3-2/Acc. to EN 62384 |
Protection class | II |
Type of protection | IP20 |
Temperature range at storage | -20 +75 °C |
DR AY PC-PFM-CLAMP DUO | 4058075313170 |
Product code | Packaging unit Piece / unit |
Dimensions in h x w x l | Gross weight | Volume |
---|---|---|---|---|
4058075239814 | FS 1 |
46mm x 34mm x 100mm | 104.00g | 0.16dm³ |
4058075239821 | VS 10 |
247mm x 118mm x 91mm | 1198.00g | 2.65dm³ |
4058075254800 | VS5 60 |
372mm x 262mm x 205mm | 7678.00g | 19.98dm³ |
EAN | SEG number | STK number | ELDAS number |
---|---|---|---|
4058075239814 | 7981954 | 4031415 | 919390290 |
References / Links
For Guarantee see www.ledvance.com/guarantee