Product description | Nominal voltage | Mains frequency | Input voltage AC | Total harmonic distortion | Power factor λ |
---|---|---|---|---|---|
Element LD 15/220 240/350 | 220 240V | 50 60Hz | 220 240V | < 30% | 0.95 |
Element LD 20/220 240/500 | 220 240V | 50 60Hz | 220 240V | < 30% | 0.98 |
Element LD 30/220 240/700 | 220 240V | 50 60Hz | 220 240V | < 20% | 0.98 |
Element LD 38/220 240/900 | 220 240V | 50 60Hz | 220 240V | < 20% | 0.98 |
Element LD 45/220 240/1A0 | 220 240V | 50 60Hz | 220 240V | < 20% | 0.98 |
Element LD 60/220 240/1A4 | 220 240V | 50 60Hz | 220 240V | < 10% | 0.98 |
Nominal voltage | 220 240 V |
Mains frequency | 50 60 Hz |
Input voltage AC |
220
240 V
|
Total harmonic distortion | < 30 % |
Power factor λ |
0.95
|
ECG efficiency |
>87 %
|
Device power loss |
2.6 W
|
Inrush current |
< 16 A
|
Max. ECG no. on circuit breaker 10 A (B) | 32 |
Max. ECG no. on circuit breaker 16 A (B) | 50 |
Max. ECG no. on circuit breaker 25 A (B) | - |
Surge capability (L/N-Ground) | 1 kV |
Surge capability (L-N) | 0.5 kV |
Nominal output voltage |
21
42 V
|
U-OUT (working voltage) | 60 V |
Nominal output current | 350 mA |
Output current tolerance | ±10 % |
Output ripple current (100 Hz) | 40 % |
Nominal output power | 15 W |
Galvanic isolation | SELV |
Galvanic isolation primary/secondary | 3.75 kV |
Length | 115.0 mm |
Width | 45.0 mm |
Height | 25.0 mm |
Mounting hole spacing, length | 105.0 mm |
Mounting hole spacing, width | 33.0 mm |
Cable cross-section, input side | 0.5 1.5 mm² |
Cable cross-section, output side | 0.5 1.5 mm² |
Product weight | 90.00 g |
Wire preparation length, input side | 8.0 9.0 mm |
Wire preparation length, output side | 8.0 9.0 mm |
Casing material | Plastic |
Ambient temperature range | -10 +50 °C |
Maximum temperature at tc test point | 75 °C |
Max.housing temperature in case of fault | 110 °C |
Permitted rel. humidity during operation |
5
85 %
|
ECG lifetime |
30000 h
|
Encapsulated | No |
Dimmable | No |
Overheating protection | Automatic switch off, reversible by manual mains reset |
Overload protection | Automatic switch off, reversible by manual mains reset |
Short-circuit protection | Automatic reversible |
No-load proof | Yes |
Max. cable length to lamp/LED module | 2.0 m |
Suitable for fixtures with prot. class | I / II |
Type of connection, output side | Push terminal |
Approval marks – approval | CCC / CE / ENEC 10 / RCM |
Standards | Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to IEC 61000-3-2/Acc. to CISPR 15/Acc. to IEC 61000-3-3/Acc. to IEC 61547 |
Protection class | II |
Type of protection | IP20 |
Temperature range at storage | -10 75 °C |
Product code | Packaging unit Piece / unit |
Dimensions in h x w x l | Gross weight | Volume |
---|---|---|---|---|
4052899947085 | UNV 1 |
90.00g | ||
4052899947153 | VS 20 |
240mm x 237mm x 72mm | 1984.00g | 4.10dm³ |
EAN | EFO number | ELDAS number |
---|---|---|
4052899947085 | 6608515 | 941791200 |