QTi 2X28/54 DIM

Product benefits
  • Same luminous flux with direct and alternating current
  • Perfect lamp start for applications with motion sensors
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Very high efficiency thanks to cut-off technology
  • Automatic restart after lamp replacement
  • ECGs comply with MINERGIE standard due to very low standby consumption
  • Configurable emergency power characteristics

PRODUCT DETAILS

Electrical data

Nominal wattage 169.00 W
Nominal voltage 220…240 V
Input voltage AC 198…264 V
Input voltage DC 154…276 V
Type of current AC/DC
Inrush current 45 A
Mains frequency 50/60 Hz
Max. ECG no. on circuit breaker 10 A (B) 8 1)
Max. ECG no. on circuit breaker 16 A (B) 13 1)
Operating frequency 44…120 kHz

1) Type B

Light technical data

Starting time [PIM] 0.6 s

Dimensions & Weight

Length 423.00 mm
Mounting hole spacing, length 415,0 mm
Width 30.00 mm
Height 21.00 mm
Cable cross-section, input side 0.5…1.5 mm², 0,5…1,0 mm² 1)
Cable cross-section, output side 0.5…1.5 mm², 0,5…1,0 mm² 1)
Wire preparation length, input side 8.0…9.0 mm 2)
Wire preparation length, output side 8.0…9.0 mm 2)
Product weight 373.00 g

1) Solid leads / Flexible
2) Combi wiring

Colors & materials

Casing material Metal
Body material Metal

Temperatures & operating conditions

Ambient temperature range +10…+50 °C
Maximum temperature at tc test point 75 °C
Max.housing temperature in case of fault 110 °C
Permitted rel. humidity during operation 5…85 % 1)

1) Maximum 56 days/year at 85 %

Lifespan

ECG lifetime 100000 h 1)

1) At Tcase = 65°C at Tc point / 10% failure rate

Capabilities

Dimmable Yes
Dimming interface 1…10 V
Dimming range 1…100 % 1)
Overheating protection Power reduction and switch off at T > 75 °C at the tc point
Overload protection Automatic switch off, reversible
Max. cable length to lamp/LED module 1.0 m / 1.5 m
Suitable for fixtures with prot. class I
Suitable for emergency lighting Yes
End of lamp life safety shutdown EOL T.2

1) Luminous flux

Certificates & Standards

Approval marks – approval VDE, VDE-EMC, EL, EAC, RCM, CCC
Standards Acc. to EN 55015; EN 55022, Acc. to EN 61547, Acc. to IEC 61000-3-2/EN 61000-3-2
Protection class I/II
Type of protection IP20
Energy efficiency class A1
EEI – Energy Label A1 BAT

LOGISTICAL DATA

Temperature range at storage -40…+85 °C

PRODUCT SHEET RELATING TO ENVIRONMENTAL QUALITIES AND CHARACTERISTICS

Quantity of precious metals 0 mg
Quantity of rare earths 0 mg
Minimum rate of recycled material in packaging 80 % 1)
Minimum percentage of recycled content in the product 0 % 1)
Product recyclability Mostly recyclable product 1)
Packaging recyclability Mostly recyclable packaging 1)
List of dangerous substances contained in the product in concentrations greater than 0.1% in mass percentage No
Contains substances of very high concern in concentrations greater than 0.1% by mass percentage Yes
List of substances of very high concern in concentrations greater than 0.1% in mass percentage Lead (7439-92-1)

1) According to AGEC Decree 2022-748 (French Anti-Waste-Legislation for a Circular Economy)

Product benefits
  • Same luminous flux with direct and alternating current
  • Perfect lamp start for applications with motion sensors
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Very high efficiency thanks to cut-off technology
  • Automatic restart after lamp replacement
  • ECGs comply with MINERGIE standard due to very low standby consumption
  • Configurable emergency power characteristics
Areas of application
  • Suitable for emergency installations
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Suitable for luminaires of protection class I
Product features
  • Control via 1…10 V interface
  • Supply voltage: 220…240 V
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Line voltage: 198…264 V
  • Dimming range: 1…100 % luminous flux
  • Lamp start: within 0.6 s
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Automatic shutdown of defective lamps and at end of life (EoL T.2)
  • Energy Efficiency Index EEI: A1 BAT
  • Overtemperature protection: Thermal management at high tc temperatures
  • Safety: to EN 61347-2-3
  • Lamp operation: to EN 60929
  • RI suppression: to EN 55015:2006+A1:2007+A2:2009/CISPR 15
  • Line harmonics according to EN 61000-3-2
  • Immunity according to EN 61547
Product code Packaging unit (Pieces/Unit) Dimensions (length x width x height) Gross weight Volume
4050300870717 Unpacked
1
373.00 g
4050300870724 Shipping box
20
435 mm x 96 mm x 170 mm 8242.00 g 7.10 dm³
EAN SEG number STK number EFO number ELDAS number
4050300870717 7980252 4030254 3322259 919484960